Site acceptance testing · installed network · end-to-end integration

IEC 61850 SAT testing for installed-system evidence.

Use ARSAS to reconfirm live IED communication after installation, verify selected values and reports, inspect GOOSE traffic, test approved control paths and isolate site-specific integration problems.

EndpointsConfirm installed addresses and independent associations
ReportsRevalidate DataSet and RCB behavior at site
Station busInspect GOOSE identity, sequence and payload
DiagnosticsSeparate network, service and IED-level problems
Suggested workflow

Reconfirm what changed between factory and site.

Installation, network addressing, gateway mappings, switch configuration and final project files can introduce differences that were not present during FAT.

01

Verify endpoint access

Confirm approved IP addresses, interfaces and independent MMS associations for the installed devices.

02

Compare configured and live context

Use available SCL as project intent while checking the data model and services actually exposed by the IED.

03

Validate reports and values

Confirm required DataSet coverage, RCB state, quality, timestamps and reason-for-inclusion evidence.

04

Inspect GOOSE behavior

Check APPID, VLAN, destination MAC, sequence counters, retransmission and ordered payload against the site design.

05

Isolate integration failures

Use per-IED diagnostics to distinguish association, report, frame, gateway, file-service and command-completion problems.

ARSAS monitoring multiple installed IEC 61850 IEDs during site acceptance testing

Independent sessions across installed devices

Keep model, monitoring, reporting, events, files and diagnostics attributable to each IED while validating the integrated substation system.

Useful for

End-to-end site validation.

  • Installed relay and bay-controller connectivity
  • SCADA and gateway signal-path investigation
  • GOOSE subscription and station-bus checks
  • Control completion and feedback evidence
  • Disturbance-record accessibility
Boundary

SAT remains a controlled project activity.

ARSAS does not replace approved site procedures, network-security authorization, injection testing, wiring checks, protection-setting verification, switching control or customer acceptance records.

Related workflows

Continue with commissioning and integration.

Verified stable release

Download ARSAS 1.6.17 for Windows.

Use the installer for a normal workstation, choose the portable ZIP for a controlled folder deployment, and verify the published SHA-256 before use.

What’s new, limitations and signing status →